Telemonitoraggio
0.1.0 - ballot

Telemonitoraggio - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Example Bundle: EsempioBundleTesserinoDispositivo


Document Subject

Generated Narrative: Patient 2e7e0fe3-f0bf-4e0a-8228-b8e7fcec8c82

Maria Rossi Female, DoB: 1971-05-01 ( http://hl7.it/sid/codiceFiscale#RSSMRA71E01F205E)


Contact Detail
Emergency Contact:
  • Luigi Rossi
  • ph: 3312345567
Emergency Contact:
  • Maria Bianchi
  • ph: 3311234598
Patient Birth PlaceVia della Vittoria, 1 Milano Italia 20100 IT

Document Content

Generated Narrative: Composition composition-tesserinodisp

status: Final

type: Telehealth Note

date: 2025-11-07 10:20:00+0100

author: PractitionerRole

title: EsempioCompositionTesserino

Attesters

-ModeTimeParty
*Legal2025-11-07 10:20:00+0100PractitionerRole

Informazioni sul dispositivo


Additional Resources Included in Document


Entry 2 - fullUrl = http://example.org/fhir/Device/device-bilancia

Resource Device:

Generated Narrative: Device device-bilancia

definition: DeviceDefinition: manufacturer[x] = ->Organization Acme Health S.p.A.; modelNumber = ACME-B100; type = Weighing patient

UdiCarriers

-DeviceIdentifierIssuerCarrierHRF
*12345678901234urn:oid:1.3.160.10.3(01)12345678901234(21)SN-B100-00987

status: Active

manufacturer: Acme Health

manufactureDate: 2025-01-15

lotNumber: LOT-2025-01-A

serialNumber: SN-B100-00987

deviceName

name: Bilancia Connessa ACME-B100

type: User Friendly name

deviceName

name: ACME-B100

type: Model name

type: Weighing patient

owner: Organization Ospedale Sandro Pertini


Entry 3 - fullUrl = http://example.org/fhir/Patient/2e7e0fe3-f0bf-4e0a-8228-b8e7fcec8c82

Resource Patient:

Generated Narrative: Patient 2e7e0fe3-f0bf-4e0a-8228-b8e7fcec8c82

Maria Rossi Female, DoB: 1971-05-01 ( http://hl7.it/sid/codiceFiscale#RSSMRA71E01F205E)


Contact Detail
Emergency Contact:
  • Luigi Rossi
  • ph: 3312345567
Emergency Contact:
  • Maria Bianchi
  • ph: 3311234598
Patient Birth PlaceVia della Vittoria, 1 Milano Italia 20100 IT

Entry 4 - fullUrl = http://example.org/fhir/PractitionerRole/practrole-bianchi-tm

Resource PractitionerRole:

Generated Narrative: PractitionerRole practrole-bianchi-tm

active: true

period: 2025-01-01 --> 2026-12-31

practitioner: Practitioner Laura Bianchi

organization: Organization Ospedale Sandro Pertini

code: Medico Referente Telemonitoraggio

specialty: Cardiochirurgia


Entry 5 - fullUrl = http://example.org/fhir/DeviceUseStatement/7cbbe77d-dcdb-409b-a215-devusestat

Resource DeviceUseStatement:

Generated Narrative: DeviceUseStatement 7cbbe77d-dcdb-409b-a215-devusestat

status: Active

subject: Maria Rossi Female, DoB: 1971-05-01 ( http://hl7.it/sid/codiceFiscale#RSSMRA71E01F205E)

timing: 2025-11-07 10:20:00+0100 --> (ongoing)

device: Device: status = active; manufacturer = Acme Health; manufactureDate = 2025-01-15; lotNumber = LOT-2025-01-A; serialNumber = SN-B100-00987; type = Weighing patient