Telemonitoraggio
0.1.0 - ballot
Telemonitoraggio - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Official URL: http://hl7.it/fhir/telemonitoraggio/StructureDefinition/DeviceTelemonitoraggio | Version: 0.1.0 | |||
| Draft as of 2024-04-29 | Computable Name: DeviceTelemonitoraggio | |||
Profilo base del Device condiviso in tutti i documenti di Telemedicina
Usages:
You can also check for usages in the FHIR IG Statistics
Description of Profiles, Differentials, Snapshots and how the different presentations work.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
0..* | (Complex) | Device Technical Check URL: http://hl7.it/fhir/telemonitoraggio/StructureDefinition/device-technical-check | |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
0..* | Identifier | Identificativo business del Device | |
![]() ![]() |
0..1 | Reference(DeviceDefinition - Telemonitoraggio) | Riferimento alla definizione (o modello) del dispositivo | |
![]() ![]() |
Σ | 0..* | BackboneElement | L'UDI utilizza il formato “identificazione automatica e raccolta dei dati” (AIDC), ad esempio codici a barre lineari o 2D e l'identificativo del dispositivo UDI (UDI-DI) utilizza un formato leggibile dall'uomo |
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
![]() ![]() |
0..1 | string | Informazioni del fabbricante. | |
![]() ![]() |
0..1 | dateTime | Data di fabbricazione | |
![]() ![]() |
0..1 | dateTime | Data di scadenza (se applicabile) | |
![]() ![]() |
0..1 | string | Numero di lotto | |
![]() ![]() |
0..1 | string | Numero seriale | |
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |
![]() ![]() ![]() |
0..1 | BackboneElement | Denominazione del dispositivo (user-friendly) | |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | Nome del dispositivo | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: user-friendly-name | |
![]() ![]() ![]() |
0..1 | BackboneElement | Modello del dispositivo | |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | Nome del modello | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: model-name | |
![]() ![]() |
0..1 | CodeableConcept | Tipologia del device Binding: DeviceType (example): Codes to identify medical devices. | |
![]() ![]() |
0..* | BackboneElement | Parametri tecnici del dispositivo | |
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
![]() ![]() |
0..1 | Reference(PatientTelemonitoraggio) | paziente a cui il device è stato assegnato | |
![]() ![]() |
0..1 | Reference(OrganizationT2) | Nome e indirizzo dell’istituzione sanitaria che ha effettuato l’assegnazione del dispositivo in oggetto | |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.deviceName:nomeDelDevice.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.deviceName:modelloDelDevice.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
This structure is derived from Device
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
Device | |||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
0..* | (Complex) | Device Technical Check URL: http://hl7.it/fhir/telemonitoraggio/StructureDefinition/device-technical-check | |
![]() ![]() |
0..* | Identifier | Identificativo business del Device | |
![]() ![]() |
0..1 | Reference(DeviceDefinition - Telemonitoraggio) | Riferimento alla definizione (o modello) del dispositivo | |
![]() ![]() |
0..* | BackboneElement | L'UDI utilizza il formato “identificazione automatica e raccolta dei dati” (AIDC), ad esempio codici a barre lineari o 2D e l'identificativo del dispositivo UDI (UDI-DI) utilizza un formato leggibile dall'uomo | |
![]() ![]() |
0..1 | string | Informazioni del fabbricante. | |
![]() ![]() |
0..1 | dateTime | Data di fabbricazione | |
![]() ![]() |
0..1 | dateTime | Data di scadenza (se applicabile) | |
![]() ![]() |
0..1 | string | Numero di lotto | |
![]() ![]() |
0..1 | string | Numero seriale | |
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |
![]() ![]() ![]() |
0..1 | BackboneElement | Denominazione del dispositivo (user-friendly) | |
![]() ![]() ![]() ![]() |
1..1 | string | Nome del dispositivo | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Required Pattern: user-friendly-name | |
![]() ![]() ![]() |
0..1 | BackboneElement | Modello del dispositivo | |
![]() ![]() ![]() ![]() |
1..1 | string | Nome del modello | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Required Pattern: model-name | |
![]() ![]() |
0..1 | CodeableConcept | Tipologia del device | |
![]() ![]() |
0..* | BackboneElement | Parametri tecnici del dispositivo | |
![]() ![]() |
0..1 | Reference(PatientTelemonitoraggio) | paziente a cui il device è stato assegnato | |
![]() ![]() |
0..1 | Reference(OrganizationT2) | Nome e indirizzo dell’istituzione sanitaria che ha effettuato l’assegnazione del dispositivo in oggetto | |
Documentation for this format | ||||
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
0..* | (Complex) | Device Technical Check URL: http://hl7.it/fhir/telemonitoraggio/StructureDefinition/device-technical-check | |||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
0..* | Identifier | Identificativo business del Device | |||||
![]() ![]() |
0..1 | Reference(DeviceDefinition - Telemonitoraggio) | Riferimento alla definizione (o modello) del dispositivo | |||||
![]() ![]() |
Σ | 0..* | BackboneElement | L'UDI utilizza il formato “identificazione automatica e raccolta dei dati” (AIDC), ad esempio codici a barre lineari o 2D e l'identificativo del dispositivo UDI (UDI-DI) utilizza un formato leggibile dall'uomo | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
![]() ![]() |
0..1 | string | The distinct identification string | |||||
![]() ![]() |
0..1 | string | Informazioni del fabbricante. | |||||
![]() ![]() |
0..1 | dateTime | Data di fabbricazione | |||||
![]() ![]() |
0..1 | dateTime | Data di scadenza (se applicabile) | |||||
![]() ![]() |
0..1 | string | Numero di lotto | |||||
![]() ![]() |
0..1 | string | Numero seriale | |||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() ![]() |
0..1 | BackboneElement | Denominazione del dispositivo (user-friendly) | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | Nome del dispositivo | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: user-friendly-name | |||||
![]() ![]() ![]() |
0..1 | BackboneElement | Modello del dispositivo | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | Nome del modello | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: model-name | |||||
![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() |
0..1 | string | The part number of the device | |||||
![]() ![]() |
0..1 | CodeableConcept | Tipologia del device Binding: DeviceType (example): Codes to identify medical devices. | |||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||
![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||
![]() ![]() ![]() |
1..1 | string | The version text | |||||
![]() ![]() |
0..* | BackboneElement | Parametri tecnici del dispositivo | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() |
0..1 | Reference(PatientTelemonitoraggio) | paziente a cui il device è stato assegnato | |||||
![]() ![]() |
0..1 | Reference(OrganizationT2) | Nome e indirizzo dell’istituzione sanitaria che ha effettuato l’assegnazione del dispositivo in oggetto | |||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||
![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| Device.udiCarrier.entryType | Base | required | UDIEntryType | 📍4.0.1 | FHIR Std. |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.statusReason | Base | extensible | FHIRDeviceStatusReason | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.deviceName:nomeDelDevice.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.deviceName:modelloDelDevice.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
This structure is derived from Device
Summary
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Key Elements View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
0..* | (Complex) | Device Technical Check URL: http://hl7.it/fhir/telemonitoraggio/StructureDefinition/device-technical-check | |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
0..* | Identifier | Identificativo business del Device | |
![]() ![]() |
0..1 | Reference(DeviceDefinition - Telemonitoraggio) | Riferimento alla definizione (o modello) del dispositivo | |
![]() ![]() |
Σ | 0..* | BackboneElement | L'UDI utilizza il formato “identificazione automatica e raccolta dei dati” (AIDC), ad esempio codici a barre lineari o 2D e l'identificativo del dispositivo UDI (UDI-DI) utilizza un formato leggibile dall'uomo |
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
![]() ![]() |
0..1 | string | Informazioni del fabbricante. | |
![]() ![]() |
0..1 | dateTime | Data di fabbricazione | |
![]() ![]() |
0..1 | dateTime | Data di scadenza (se applicabile) | |
![]() ![]() |
0..1 | string | Numero di lotto | |
![]() ![]() |
0..1 | string | Numero seriale | |
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |
![]() ![]() ![]() |
0..1 | BackboneElement | Denominazione del dispositivo (user-friendly) | |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | Nome del dispositivo | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: user-friendly-name | |
![]() ![]() ![]() |
0..1 | BackboneElement | Modello del dispositivo | |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | Nome del modello | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: model-name | |
![]() ![]() |
0..1 | CodeableConcept | Tipologia del device Binding: DeviceType (example): Codes to identify medical devices. | |
![]() ![]() |
0..* | BackboneElement | Parametri tecnici del dispositivo | |
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
![]() ![]() |
0..1 | Reference(PatientTelemonitoraggio) | paziente a cui il device è stato assegnato | |
![]() ![]() |
0..1 | Reference(OrganizationT2) | Nome e indirizzo dell’istituzione sanitaria che ha effettuato l’assegnazione del dispositivo in oggetto | |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.deviceName:nomeDelDevice.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.deviceName:modelloDelDevice.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Differential View
This structure is derived from Device
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
Device | |||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
0..* | (Complex) | Device Technical Check URL: http://hl7.it/fhir/telemonitoraggio/StructureDefinition/device-technical-check | |
![]() ![]() |
0..* | Identifier | Identificativo business del Device | |
![]() ![]() |
0..1 | Reference(DeviceDefinition - Telemonitoraggio) | Riferimento alla definizione (o modello) del dispositivo | |
![]() ![]() |
0..* | BackboneElement | L'UDI utilizza il formato “identificazione automatica e raccolta dei dati” (AIDC), ad esempio codici a barre lineari o 2D e l'identificativo del dispositivo UDI (UDI-DI) utilizza un formato leggibile dall'uomo | |
![]() ![]() |
0..1 | string | Informazioni del fabbricante. | |
![]() ![]() |
0..1 | dateTime | Data di fabbricazione | |
![]() ![]() |
0..1 | dateTime | Data di scadenza (se applicabile) | |
![]() ![]() |
0..1 | string | Numero di lotto | |
![]() ![]() |
0..1 | string | Numero seriale | |
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |
![]() ![]() ![]() |
0..1 | BackboneElement | Denominazione del dispositivo (user-friendly) | |
![]() ![]() ![]() ![]() |
1..1 | string | Nome del dispositivo | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Required Pattern: user-friendly-name | |
![]() ![]() ![]() |
0..1 | BackboneElement | Modello del dispositivo | |
![]() ![]() ![]() ![]() |
1..1 | string | Nome del modello | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Required Pattern: model-name | |
![]() ![]() |
0..1 | CodeableConcept | Tipologia del device | |
![]() ![]() |
0..* | BackboneElement | Parametri tecnici del dispositivo | |
![]() ![]() |
0..1 | Reference(PatientTelemonitoraggio) | paziente a cui il device è stato assegnato | |
![]() ![]() |
0..1 | Reference(OrganizationT2) | Nome e indirizzo dell’istituzione sanitaria che ha effettuato l’assegnazione del dispositivo in oggetto | |
Documentation for this format | ||||
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device | Item used in healthcare | |||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
0..* | (Complex) | Device Technical Check URL: http://hl7.it/fhir/telemonitoraggio/StructureDefinition/device-technical-check | |||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
0..* | Identifier | Identificativo business del Device | |||||
![]() ![]() |
0..1 | Reference(DeviceDefinition - Telemonitoraggio) | Riferimento alla definizione (o modello) del dispositivo | |||||
![]() ![]() |
Σ | 0..* | BackboneElement | L'UDI utilizza il formato “identificazione automatica e raccolta dei dati” (AIDC), ad esempio codici a barre lineari o 2D e l'identificativo del dispositivo UDI (UDI-DI) utilizza un formato leggibile dall'uomo | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
![]() ![]() |
0..1 | string | The distinct identification string | |||||
![]() ![]() |
0..1 | string | Informazioni del fabbricante. | |||||
![]() ![]() |
0..1 | dateTime | Data di fabbricazione | |||||
![]() ![]() |
0..1 | dateTime | Data di scadenza (se applicabile) | |||||
![]() ![]() |
0..1 | string | Numero di lotto | |||||
![]() ![]() |
0..1 | string | Numero seriale | |||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() ![]() |
0..1 | BackboneElement | Denominazione del dispositivo (user-friendly) | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | Nome del dispositivo | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: user-friendly-name | |||||
![]() ![]() ![]() |
0..1 | BackboneElement | Modello del dispositivo | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | Nome del modello | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: model-name | |||||
![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() |
0..1 | string | The part number of the device | |||||
![]() ![]() |
0..1 | CodeableConcept | Tipologia del device Binding: DeviceType (example): Codes to identify medical devices. | |||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||
![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||
![]() ![]() ![]() |
1..1 | string | The version text | |||||
![]() ![]() |
0..* | BackboneElement | Parametri tecnici del dispositivo | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() |
0..1 | Reference(PatientTelemonitoraggio) | paziente a cui il device è stato assegnato | |||||
![]() ![]() |
0..1 | Reference(OrganizationT2) | Nome e indirizzo dell’istituzione sanitaria che ha effettuato l’assegnazione del dispositivo in oggetto | |||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||
![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| Device.udiCarrier.entryType | Base | required | UDIEntryType | 📍4.0.1 | FHIR Std. |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.statusReason | Base | extensible | FHIRDeviceStatusReason | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.deviceName:nomeDelDevice.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.deviceName:modelloDelDevice.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
This structure is derived from Device
Summary
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron