 a fhir:Device ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "device-bilancia"] ; # 
  fhir:meta [
    ( fhir:profile [
fhir:v "http://hl7.it/fhir/telemonitoraggio/StructureDefinition/DeviceTelemonitoraggio"^^xsd:anyURI ;
fhir:link <http://hl7.it/fhir/telemonitoraggio/StructureDefinition/DeviceTelemonitoraggio>     ] )
  ] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Device device-bilancia</b></p><a name=\"device-bilancia\"> </a><a name=\"hcdevice-bilancia\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\"/><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-DeviceTelemonitoraggio.html\">DeviceTelemonitoraggio</a></p></div><p><b>definition</b>: <a href=\"DeviceDefinition-EsempioDeiceDefinitionBilancia.html\">DeviceDefinition: manufacturer[x] = -&gt;Organization Acme Health S.p.A.; modelNumber = ACME-B100; type = Weighing patient</a></p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>CarrierHRF</b></td></tr><tr><td style=\"display: none\">*</td><td>12345678901234</td><td>urn:oid:1.3.160.10.3</td><td>(01)12345678901234(21)SN-B100-00987</td></tr></table><p><b>status</b>: Active</p><p><b>manufacturer</b>: Acme Health</p><p><b>manufactureDate</b>: 2025-01-15</p><p><b>lotNumber</b>: LOT-2025-01-A</p><p><b>serialNumber</b>: SN-B100-00987</p><blockquote><p><b>deviceName</b></p><p><b>name</b>: Bilancia Connessa ACME-B100</p><p><b>type</b>: User Friendly name</p></blockquote><blockquote><p><b>deviceName</b></p><p><b>name</b>: ACME-B100</p><p><b>type</b>: Model name</p></blockquote><p><b>type</b>: <span title=\"Codes:{http://snomed.info/sct 39857003}\">Weighing patient</span></p><p><b>owner</b>: <a href=\"Organization-osp-pertini.html\">Organization Ospedale Sandro Pertini</a></p></div>"^^rdf:XMLLiteral
  ] ; # 
  fhir:definition [
fhir:reference [ fhir:v "DeviceDefinition/EsempioDeiceDefinitionBilancia" ]
  ] ; # 
  fhir:udiCarrier ( [
fhir:deviceIdentifier [ fhir:v "12345678901234" ] ;
fhir:issuer [ fhir:v "urn:oid:1.3.160.10.3"^^xsd:anyURI ] ;
fhir:carrierHRF [ fhir:v "(01)12345678901234(21)SN-B100-00987" ]
  ] ) ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:manufacturer [ fhir:v "Acme Health"] ; # 
  fhir:manufactureDate [ fhir:v "2025-01-15"^^xsd:date] ; # 
  fhir:lotNumber [ fhir:v "LOT-2025-01-A"] ; # 
  fhir:serialNumber [ fhir:v "SN-B100-00987"] ; # 
  fhir:deviceName ( [
fhir:name [ fhir:v "Bilancia Connessa ACME-B100" ] ;
fhir:type [ fhir:v "user-friendly-name" ]
  ] [
fhir:name [ fhir:v "ACME-B100" ] ;
fhir:type [ fhir:v "model-name" ]
  ] ) ; # 
  fhir:type [
    ( fhir:coding [
a sct:39857003 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "39857003" ] ;
fhir:display [ fhir:v "Weighing patient" ]     ] )
  ] ; # 
  fhir:owner [
fhir:reference [ fhir:v "Organization/osp-pertini" ]
  ] . #